Pharmaceuticals and healthcare
GDP-compliant transport of medicines and vaccines, blood banks, clinical trials, pharmacies and wholesalers.
Product range / Temperature and humidity data loggers
Electronic data loggers record complete temperature and humidity profiles during pharmaceutical and food transport, in dry ice down to −100 °C, in warehouses, and during pasteurisation and sterilisation up to +130 °C. Models compliant with EN 12830 and FDA 21 CFR Part 11, with NIST calibration.
Practical applications
The logger records temperature or humidity throughout the process and generates a report that can be included in quality documentation, claims or audits. We select the model to suit the measurement range, data retrieval method and operating conditions.
GDP-compliant transport of medicines and vaccines, blood banks, clinical trials, pharmacies and wholesalers.
Dry ice shipments, −80 °C ultra-low-temperature freezers, biological samples and plasma.
Pasteurisation in breweries and bottling plants, canned food, smokehouses, cooking, cold stores and food transport.
Temperature and humidity monitoring in warehouses, industrial halls, archives and museums.
Cycle monitoring for autoclaves, sterilisers and washers in healthcare and laboratories.

Full product range details
An electronic temperature data logger records the complete profile of monitored conditions, with a date and time for each measurement. This shows not only whether an excursion occurred, but also when and for how long. These records form the basis of documentation for pharmaceutical transport under Good Distribution Practice (GDP), HACCP systems, thermal process validation and warehouses requiring humidity monitoring.
The range covers four groups: USB transport loggers with automatic PDF reports (iMiniPlus PDF), dry ice loggers down to −100 °C (iMiniPlus Dry Ice), temperature and humidity loggers with alarms (iMINI, iLog), and steel process loggers for pasteurisation, cooking and autoclaves up to +130 °C (KeyTag Kt1HT, Escort Junior). Models meet the requirements of EN 12830 and FDA 21 CFR Part 11, and calibration can be verified with a NIST certificate.
Monitoring vaccine temperatures in a clinic, pharmacy or vaccination centre requires continuous recording within the +2…+8 °C range — including overnight and on non-working days. A logger with an alarm shows when and for how long the refrigerator temperature was outside the required range, while a printout or PDF file provides evidence for public health inspections. The same requirement to document temperature applies to cold rooms in funeral homes, mortuaries and post-mortem facilities.
In breweries and food processing plants, immersion-resistant loggers (IP68) are placed inside a bottle, can or jar passing through a pasteurisation tunnel. Recording the product temperature allows pasteurisation units (PU) to be calculated and process effectiveness to be verified.

SUS 304 steel high-temperature data logger with two probes
How it works
Highly accurate, reusable data logger made from food-contact-approved stainless steel, with two external probes: a 60 mm top probe (rounded Ø 5 mm tip) and a 25 mm side probe. Used to monitor pasteurisation, cooking, smoking and sterilisation — for example, inside a jar, can or product in an autoclave. When connected via USB, it works like a USB flash drive and automatically generates PDF, CSV and TXT reports. Each unit is calibrated at 4 points (60, 80, 100 and 120 °C) and supplied with a calibration certificate.
Application and use
For measuring temperature inside the product during pasteurisation, cooking, smoking and autoclaving — up to +130 °C. Start the logger before transport and position it as close as possible to the goods being monitored. After delivery, retrieve the data using the selected reporting method.
| Measurement range | −40 °C to +130 °C |
|---|---|
| Accuracy | ±0.3 °C (full range) |
| Resolution | 0.01 °C |
| Memory | over 45 500 readings |
| Logging interval | 5 s – 24 h |
| Alarms | 4 thresholds (continuous and/or cumulative) |
| Sensor response time | 20 s (T90, oil bath) |
| Start | via software, when a temperature is reached or at a set time |
| Files | PDF, CSV, TXT, KLG — generated automatically |
| Battery | 3 V BR2450A, replaceable |
| Dimensions / weight | 91.7 × 12.7 × 51 mm / 250 g |
| Software | KeyTag Manager (Windows, macOS, Linux), free |
| Calibration | 4 points, certificate included in the PDF report |
Data based on the manufacturer's documentation. Full datasheets are available in the documentation below.
Product FAQ
For measuring temperature inside the product during pasteurisation, cooking, smoking and autoclaving — up to +130 °C.
The key factors are measurement range, transit time, logging interval, report retrieval method, and the need for alarms and location tracking. Key features of this solution include range −40 °c to +130 °c, accuracy ±0.3 °c across the full range and resolution 0.01 °c, sts40 digital sensor.

IP68 waterproof data logger in 316 steel with interchangeable probes
How it works
A family of high-temperature data loggers up to +125 °C, with a steel base and one or two probes of any length. Probes are easy to unscrew and replace — axial probes of 25, 60 or 80 mm, M6 threaded probes for screwing into a can or jar, and L- and U-shaped probes. Withstands immersion (pressure-tested to 40 m, 5 bar), making it suitable for pasteurisation tunnels, kettles and autoclaves.
Application and use
For pasteurisation of bottles, cans and jars, and submerged operation (IP68) up to +125 °C. Start the logger before transport and position it as close as possible to the goods being monitored. After delivery, retrieve the data using the selected reporting method.
| Measurement range | 0 °C to +125 °C |
|---|---|
| Accuracy | ±0.35 °C (0–70 °C), ±0.40 °C (70–100 °C), ±0.55 °C (100–125 °C) |
| Resolution | 0.5 °C |
| Memory | 16 000 or 40 000 readings |
| Logging interval | 5–59 s or 1–255 min |
| Housing | 316 stainless steel and PEEK polymer |
| Dimensions / weight | Ø 49 × 28 mm (excluding probe) / 250 g |
| Battery | high-temperature lithium, replaceable, 1–2 years |
| Software | Console Pro, USB interface |
| Versions | HJ-IN-V-16-CI (25 mm probe), HJ-FP-V-16-CI / CEI (M6, 60 / 80 mm), HJ-FP-V-16-CU (U-shaped probe), CAP versions |
| Calibration | NIST |
Data based on the manufacturer's documentation. Full datasheets are available in the documentation below.
Original manufacturer documentation (in English).
Product FAQ
For pasteurisation of bottles, cans and jars, and submerged operation (IP68) up to +125 °C.
The key factors are measurement range, transit time, logging interval, report retrieval method, and the need for alarms and location tracking. Key features of this solution include range 0 °c to +125 °c and ip68 protection — tested to 40 m / 5 bar.

USB data logger with automatic PDF reports — no software required
How it works
Data logger for refrigerated and pharmaceutical shipments, particularly those sent to recipients without software. When connected by USB cable, the computer recognises it as a USB flash drive. The PDF report, containing a graph, a list of readings and an alarm summary, opens in a standard PDF viewer. The large display shows the current, minimum and maximum temperatures.
Application and use
For refrigerated and pharmaceutical shipments where the recipient needs to open a PDF report without installing specialist software. Start the logger before transport and position it as close as possible to the goods being monitored. After delivery, retrieve the data using the selected reporting method.
| Measurement range | −40 °C to +70 °C |
|---|---|
| Accuracy | ±0.5 °C (−40 to −10 °C), ±0.3 °C (−10 to +70 °C) |
| Resolution | 0.1 °C |
| Sensor | internal or external |
| Logging interval | 5 s – 18 h |
| Clock | ±1 min per month |
| Start / stop | START button (with or without delay), stop function can be disabled |
| Ingress protection | IP65 (with USB cap fitted) |
| Dimensions / weight | 83 × 57 × 17 mm / 70 g |
| Versions | MU-IN-D-16-L (internal), MU-OE-D-16-L (external), MU-ST-D-8-L (single-use) |
| Warranty | 24 months (reusable versions, excluding battery) |
| Certifications | EN 12830, 21 CFR Part 11, ISO 9001:2015, CE |
Data based on the manufacturer's documentation. Full datasheets are available in the documentation below.
Original manufacturer documentation (in English).
Product FAQ
For refrigerated and pharmaceutical shipments where the recipient needs to open a PDF report without installing specialist software.
The key factors are measurement range, transit time, logging interval, report retrieval method, and the need for alarms and location tracking. Key features of this solution include range −40 °c to +70 °c, resolution 0.1 °c and pdf report without installing software.

Dry ice data logger with a probe rated down to −100 °C
How it works
Data logger for dry ice shipments (−78.5 °C) and ultra-low-temperature freezers. The steel probe on a 1-metre Teflon cable goes inside the container, while the logger and its display remain outside. Used for vaccines, biological material, laboratory samples and plasma.
Application and use
For dry ice shipments and ultra-low-temperature freezers — down to −100 °C. Start the logger before transport and position it as close as possible to the goods being monitored. After delivery, retrieve the data using the selected reporting method.
| Measurement range | −100 °C to +40 °C |
|---|---|
| Accuracy | ±1.0 °C (−100 to −80 °C), ±0.7 °C (−79 to −10 °C), ±0.6 °C (−9 to +40 °C) |
| Resolution | 0.1 °C |
| Memory | 8 048 readings |
| Logging interval | 5 s – 18 h |
| Alarms | 2 thresholds: HIGH and LOW |
| Probe response time | T90 — 5 min |
| Ingress protection | IP64 (with cap fitted) |
| Dimensions / weight | 83 × 57 × 17 mm / 70 g |
| Data retrieval | via USB–serial cable, Console Pro software |
| Versions | MP-OE-N-8-L (reusable), MP-ST-N-8-L (single-use) |
| Certifications | EN 12830, 21 CFR Part 11, ISO 9001:2015, CE, RoHS |
Data based on the manufacturer's documentation. Full datasheets are available in the documentation below.
Original manufacturer documentation (in English).
Product FAQ
For dry ice shipments and ultra-low-temperature freezers — down to −100 °C.
The key factors are measurement range, transit time, logging interval, report retrieval method, and the need for alarms and location tracking. Key features of this solution include range −100 °c to +40 °c and stainless steel probe on a 1 m teflon cable.

Data logger with 4 alarm thresholds and LED indicators
How it works
Versatile data logger for warehouses, cold stores, transport, blood banks and clinical trials. HS/HE versions measure temperature and humidity simultaneously, while an additional external probe allows temperature measurement inside the product. Two red and two blue LEDs immediately indicate excursions.
Application and use
For warehouses, cold stores and transport requiring temperature and humidity measurement with four alarm thresholds. Start the logger before transport and position it as close as possible to the goods being monitored. After delivery, retrieve the data using the selected reporting method.
| Temperature range | −40 °C to +80 °C |
|---|---|
| Humidity range | 0–100% RH |
| Temperature accuracy | ±0.5 °C (−40 to −10 °C), ±0.3 °C (−10 to +80 °C) |
| Humidity accuracy | ±3% (10–90% RH), ±4% (below 10% and above 90%) |
| Resolution | 0.1 °C / 0.1% |
| Logging interval | 5 s – 17 h |
| Start delay | 1 minute – 99 days |
| Ingress protection | IP65 (with USB cap fitted) |
| Dimensions / weight | 83 × 57 × 17 mm / 70 g |
| Software | Console Plus; PDF, TXT, CSV export |
| Versions | MX-IN, MX-ST, MX-OE, MX-1E, MX-2E (temperature), MX-HS, MX-HE (temperature and humidity) |
| Certifications | 21 CFR Part 11, ISO 9001:2008, CE, RoHS, NIST |
Data based on the manufacturer's documentation. Full datasheets are available in the documentation below.
Original manufacturer documentation (in English).
Product FAQ
For warehouses, cold stores and transport requiring temperature and humidity measurement with four alarm thresholds.
The key factors are measurement range, transit time, logging interval, report retrieval method, and the need for alarms and location tracking. Key features of this solution include temperature −40 °c to +80 °c, humidity 0–100% rh and 4 alarm thresholds: 2 red and 2 blue leds.

Data logger with audible alarm, 4 ranges and accessories
How it works
Round data logger with a large display and visual and audible alarms. Interchangeable external probes cover ranges from dry ice temperatures to +150 °C, while the HS version also measures humidity. Accessories available for iLog include a wall mount, magnetic key, alarm module with siren and strobe, and the portable iLog Chart Reader chart printer — allowing reports to be printed without a computer.
Application and use
For continuous monitoring of rooms and cold stores, with an audible alarm, external siren and report printing without a computer. Start the logger before transport and position it as close as possible to the goods being monitored. After delivery, retrieve the data using the selected reporting method.
| Temperature ranges | C: −20…+100 °C, D: −40…+70 °C, N: −100…+40 °C, Z: 0…+150 °C |
|---|---|
| Humidity | EI-HS-D-32-L version |
| Accuracy | ±0.35 °C |
| Resolution | 0.1 °C / 0.1% |
| Memory | 32 064 readings (1 sensor), 16 032 per sensor (2 sensors) |
| Logging interval | 5 s – 10 days |
| Start | with magnetic key or at a set time |
| Ingress protection | IP67 (internal sensor), IP65 (external sensor) |
| Dimensions / weight | Ø 76 × 18 mm / 68 g |
| Interface | USB (EA-INT-USB) or serial (EA-INT-U), Console Pro software |
| Accessories | EA-KEY, EA-ALK, EA-ALARM, EA-INT-HLD, EI-CR |
| Certifications | EN 12830, 21 CFR Part 11, ISO 9001:2008, CE, RoHS, NIST |
Data based on the manufacturer's documentation. Full datasheets are available in the documentation below.
Original manufacturer documentation (in English).
Product FAQ
For continuous monitoring of rooms and cold stores, with an audible alarm, external siren and report printing without a computer.
The key factors are measurement range, transit time, logging interval, report retrieval method, and the need for alarms and location tracking. Key features of this solution include ranges: c −20…+100 °c, d −40…+70 °c, n −100…+40 °c, z 0…+150 °c and rh and memory for 32 000 readings, accuracy ±0.35 °c.
Questions to consider before choosing
An indicator only shows whether a threshold has been exceeded. A data logger records each measurement with a date and time, producing a graph and report covering the entire shipment or process.
When connected via USB, iMiniPlus PDF and KeyTag Kt1HT work like USB flash drives and automatically generate PDF reports. The other models are read using the free Console Plus or Console Pro software.
iMiniPlus Dry Ice measures from −100 °C to +40 °C. The probe on a Teflon cable goes inside the container, while the logger and its display remain outside. The iLog N-range model is also suitable for dry ice.
Yes — iMiniPlus PDF, iMiniPlus Dry Ice and iLog have declared compliance with EN 12830 and 21 CFR Part 11, and iMINI with 21 CFR Part 11. Calibration can be verified with a NIST certificate.
Escort Junior has M6 threaded probes that screw into the packaging, while KeyTag Kt1HT has a 60 mm probe for insertion into the product. Both loggers have steel housings and are sealed (IP68 / IP67).
Free quotation
We help you choose the right variant and threshold for your application — we usually prepare a quotation within 1 working day. You can also call: +48 22 666 82 95.
Other product groups
Cold chain indicators
Single-use heat and cold indicators for chilled shipments.
Thermax temperature indicator strips
Eight temperature-sensitive zones for a permanent temperature record.
Liquid crystal thermometers
Reversible Digi-Temp® thermometers — horizontal and vertical, with 7, 8, 10, 13 and 16 segments, plus the Digi-Temp® EZ series.
Hygiene, sterilisation and food safety
Indicators for dishwashers, thermal disinfection and food temperature checks.
Thermochromic labels and liquid crystals
Temperature-responsive colours: labels, sheets and inks.
Thermochromic paints and pigments
Paints, pigments and coatings that change colour with temperature.
Medical and blood donation solutions
Forehead thermometers and indicators for medicines and blood containers.
ShockWatch shock indicators
Single-use ShockWatch impact indicators for shipments and products.
Shock recorders and condition monitors
ShockLog, gView and SpotBot — impact, vibration and environmental monitoring.
TiltWatch tilt indicators
TiltWatch — check whether shipments stayed upright in transit.